Chemistry Instrumentation Services: Mass Spectrometry Instrumentation
The instrumentation facility provides access to a total of 7 mass spectrometers.
(click on images below for larger version of image)
Agilent 5977 GCMS
(EEL 210)
- Source Type: electron ionization (EI)
- Column: DB-5MS (non-polar)
- Equipped with an Agilent 7890 gas chromatograph and a 150 sample autosampler.
- Capable of unit mass resolution.
- Best suited for analysis of mixtures of volatile low molecular weight compounds (<600 amu).
- Primary Contact: Michelle Thibault.
Agilent 5975 GCMS
(SB134)
- Source Type: electron ionization (EI)
- Column: DB-17MS (mid-polar)
- Equipped with an Agilent 6890 gas chromatograph and an 8 sample autosampler.
- Capable of unit mass resolution.
- Best suited for analysis of mixtures of volatile low molecular weight compounds (< 600 amu).
Agilent 5973 GCMS
(SB 038)
- Source type: electron ionization (EI)
- Column: DB-WAX (polar)
- Equipped with an Agilent 6890 gas chromatograph and a 100 sample autosampler.
- Capable of unit mass resolution.
- Best suited for analysis of mixtures of volatile low molecular weight compounds (< 600 amu).
- Primary Contact: Jian Jun (Johnson) Li.
Agilent 6550 LC-MS Q-TOF
(SB 134)
- Source Type: electrospray ionization (ESI)/ atmospheric pressure chemical ionization (APCI).
- Equipped with an Agilent 1200 series HPLC.
- Capable of high resolution and high mass accuracy.
- Tandem mass analyzers allow for controlled fragmentation of observed species.
- Best suited for analysis of relatively pure, high molecular weight compounds (> 200 amu).
Agilent 6520 LC-MS Q-TOF
(SB 134)
- Source Type: electrospray ionization (ESI)/ atmospheric pressure chemical ionization (APCI).
- Equipped with an Agilent 1200 series HPLC.
- Capable of high resolution and high mass accuracy.
- Tandem mass analyzers allow for controlled fragmentation of observed species.
- Best suited for analysis of relatively pure, high molecular weight compounds (> 200 amu).
Bruker Autoflex III Smartbeam MALDI-TOF
(SB 032)
- Source Type: matrix assisted laser desorption ionization (MALDI).
- Capable of high resolution and high mass accuracy.
- Best suited for analysis of relatively pure, high molecular weight compounds (> 400 amu).
- Primary Contact: Jian Jun (Johnson) Li.
Waters GCT Premier GC-TOF
(SB 134)
- Source Type: electron ionization (EI)/ chemical ionization (CI)
- Capable of high resolution and high mass accuracy.
- Best suited for analysis of relatively pure, low molecular weight compounds (< 600 amu).
- Primary Contact: Michelle Thibault.